BAC Cooling Tower Drift Eliminator Replacement
* Maximum operational safety
* Legal compliance
* Original thermal performance
* Easy cleaning
* Dry surroundings by minimum drift emission
- LATINO
- CHINA
- 1 WEEK
- 100000 square meter one week
- Information
- Video
- Download
BAC Cooling Tower Drift Eliminator Replacement
Core Features & Performance Highlights
Exceptional Drift Reduction Efficiency: Adopting a precision-engineered curved blade design, the eliminator achieves a drift loss rate of less than 0.001% of the circulating water flow—ten times lower than industry allowable limits. It efficiently captures droplets as small as 20μm, ensuring minimal water waste and preventing the emission of chemicals or contaminants present in the cooling water, which is crucial for meeting environmental regulations.
Low Airflow Resistance & Energy Savings: Optimized blade spacing and airflow path design minimize pressure drop, with a resistance of only 0.8mmH2O at a standard airflow velocity of 2.8m/s. This low resistance reduces the workload on tower fans, lowering energy consumption while maintaining the tower’s rated thermal performance—no compromise between efficiency and energy savings.
Durable & UV-Resistant Construction: Manufactured from high-grade PVC or FRP (Fiberglass Reinforced Plastic) infused with imported carbon black additives, the eliminator exhibits exceptional resistance to UV radiation, chemical corrosion, and thermal aging. It withstands operating temperatures up to 60℃ and maintains structural integrity in harsh industrial environments, ensuring a service life of up to 10 years under normal operating conditions.
Seamless BAC Compatibility & Easy Installation: Precisely engineered to match the dimensions and mounting points of BAC’s original drift eliminators, this replacement unit requires no modifications to the tower’s existing structure. The interlocking blade design and lightweight construction enable quick and hassle-free installation, reducing maintenance time and labor costs. It is fully compatible with BAC 3000 Series open cooling towers, Smart Series packaged towers, and other popular BAC models.
High Structural Rigidity & Clog-Resistance: Utilizing machine-extruded blades with a thickness of 0.8mm, the eliminator offers superior structural strength and overall rigidity, preventing deformation even under high airflow velocities. The smooth blade surface and optimized flow path reduce the accumulation of debris and scale, minimizing clogging risks and the need for frequent cleaning.
Technical Specifications
Parameter | Value |
Material | High-grade PVC (standard), FRP (optional) |
Drift Loss Rate | ≤0.001% of circulating water flow |
Pressure Drop (at 2.8m/s) | ≈0.8mmH2O |
Maximum Operating Temperature | 60℃ |
Blade Thickness | 0.8mm |
Critical Droplet Capture Size | ≥20μm |
Installation Type | Interlocking/Direct Fit (BAC-compatible) |
Service Life | Up to 10 years (normal conditions) |
Applicable BAC Tower Models & Industries
Compatible BAC Tower Models
BAC 3000 Series Open Cooling Towers
BAC Smart (智灵) Series Packaged Cooling Towers
BAC Industrial Crossflow & Counterflow Cooling Towers
Other BAC models (custom specifications available)
Key Application Industries
Power generation (thermal power plants, nuclear power plants)
Chemical & petrochemical industry
Metallurgy (steel mills, non-ferrous metal smelting)
Pharmaceutical & food processing
Commercial HVAC systems (hospitals, shopping malls, data centers)
Why Choose Our BAC Replacement Drift Eliminator?



Relevant Cooling Tower Drift Eliminator



Tianjin LATINO Environmental Technology Co., Ltd. are on the base of high quality, good service, we win good reputation in the industry. We help our customers better to get cooling tower products from China.We specializes in manufacturing various cooling tower and parts. Our company's cooling tower products is being used widely around the world. Our business involve in Italy, Germany, Australia, UK, Indonesia, Thailand, Belgium, France, Poland, India, Malaysia, Singapore and New Zealand, etc..
Latino has a high quality team of talents. Team members are young and energetic, with a sense of innovation and the courage to meet the challenge.Team members develop and practice new e-marketing mode, follow consumer demand, provide customers with high quality products and services.
LATINO has an experienced team in quality and project implement to support the purchasing activities of overseas customers;The company's main products are cooling tower parts, such as Film Fill, drift eliminator and spray system, UPVC distribution pipes, FPR winding splash pipe, FRP profile parts,FRP gratings, Fan stack, band & clamp, etc.; Our product are approved by CTI and we have our own patent .
Our factory has the largest capacity and have been working with the recognized brands of cooling tower in around the world, our team have rich experience in oversea projects.we were your colleague, knowing your care, your culture and your requirements.So we make it easy for you to purchase high quality and good value internal plastic parts of cooling tower in China.
Our fill has been verified by actual operation for more than ten years. It is very reliable and efficient. You can rely on us to deliver a successful project while reducing your total project costs!




