Cooling Tower Fill

  • Hot
    Cooling Tower PVC Film Fill For Counter Flow Cooling Towers

    Cooling Tower PVC Film Fill For Counter Flow Cooling Towers

    The Cooling Tower PVC Filler is probably the most thermally efficient fill worldwide, has proven its efficiency for more than 30 years.
    The sharp horizontal corrugations of cooling tower PVC filler allow even water redistribution on the sheet and water rotation for good contact with air. The offset flute design allows vertical rotation of air with limited pressure drop.
    This type of cooling tower fill well adapted to any induced draft or natural draft cooling tower using normal industrial water quality.

    Email Details
  • SNCS Fill For Counter Flow Cooling Towers

    SNCS Fill For Counter Flow Cooling Towers

    The Cooling Tower PVC Filler is probably the most thermally efficient fill worldwide, has proven its efficiency for more than 30 years.
    The sharp horizontal corrugations of cooling tower PVC filler allow even water redistribution on the sheet and water rotation for good contact with air. The offset flute design allows vertical rotation of air with limited pressure drop.
    This type of cooling tower fill well adapted to any induced draft or natural draft cooling tower using normal industrial water quality.

    Email Details
  • 820 mm Width Marley Type Mx75s PVC Fill for Cooling Tower

    820 mm Width Marley Type Mx75s PVC Fill for Cooling Tower

    820 mm Width Marley Type Mx75s PVC Fill for Cooling Tower is with cooling tower air inlet louver and drift eliminator.

    And its installation method is gluing and hanging according to the customer's request.

    Material: PP and PVC

    Email Details
  • Hot
    955mm* 705mm Cooling Tower PP Splashed Grid Fill

    955mm* 705mm Cooling Tower PP Splashed Grid Fill

    The grid fill is the result of an extensive optimization of the lath width, the blockage area ratio and the lath layout;
    The water droplets, splashing on a well drained lath, break in a large number of very small droplets, inducing large heat exchange surface. Blockage area ratio and lozenge layout is the optimized compromise between the pressure drop and the probability of large droplets to hit the laths.
    The laths height has been selected to transfer the load to the supporting spacers using minimum material quantity.
    It may be used as well in Counterflow as in Crossflow cooling towers, mechanical or natural draft.
    It is well adapted to any water quality, even without water treatment, when the fouling risk cannot be determined, in particular with seawater

    Email Details
  • Hot
    255mm* 705mm Cooling Tower PP Splashed Grid Fill

    255mm* 705mm Cooling Tower PP Splashed Grid Fill

    The grid fill is the result of an extensive optimization of the lath width, the blockage area ratio and the lath layout;
    The water droplets, splashing on a well drained lath, break in a large number of very small droplets, inducing large heat exchange surface. Blockage area ratio and lozenge layout is the optimized compromise between the pressure drop and the probability of large droplets to hit the laths.
    The laths height has been selected to transfer the load to the supporting spacers using minimum material quantity.
    It may be used as well in Counterflow as in Crossflow cooling towers, mechanical or natural draft.
    It is well adapted to any water quality, even without water treatment, when the fouling risk cannot be determined, in particular with seawater

    Email Details
  • BAC CF1200 New Type Non-Glued Conter Flow Cooling Tower Fills

    BAC CF1200 New Type Non-Glued Conter Flow Cooling Tower Fills

    This BAC CF1200 New Type Non-Glued Conter Flow Cooling Tower Fills is used in:
    - TSS is less than 100 PPM with good microbiological control (less than 25PPM where microbiological control is poor);
    - Make-up from uncontaminated sources
    - Water treatment using oxidizing biocides & scale inhibitors
    - Low cycles of concentration
    - Minimal airborne dust
    - No potential for oil or grease contamination

    Email Details
  • Hot
    Ebara Cross Cooling Tower PVC Fill Material For Ebara Cooling Towers

    Ebara Cross Cooling Tower PVC Fill Material For Ebara Cooling Towers

    Cross Cooling Tower PVC Filling Material plays a crucial role in improving the lifespan of the cross flow cooling tower. It also could increases the water flow process remarkably for better performance and efficiency as well.

    This cross flow cooling tower PVC filling material is glued together by A type and B type sheets to be a block which is stalled in tower.

    This PVC fill use the modified PVC sheet and is manufactured with a unique modified formula to enable strong resistance and guarantee its durability. It involves special processing whereby the inner side edge is integrated with a liquid baffle plate which controls the drift loss of water.

    Email Details
  • Hot
    Cross Flow Cooling Tower PVC Fill Used For Marley Cooling Towers

    Cross Flow Cooling Tower PVC Fill Used For Marley Cooling Towers

    This MX75 cooling tower fill virtually eliminates the nuisance caused by drift spotting on adjacent buildings and property. For additional savings, the drift eliminators discharge air directly toward the fan. Discharge air, traveling in the right direction when it leaves the eliminators, translates to lower fan horsepower.

    Email Details
  • Hot
    Cooling tower PP fill manufacture with high temperature resistance

    Cooling tower PP fill manufacture with high temperature resistance

    The Net fill (Non-glued assembly fill) have been specially designed for medium to strongly polluted cooling water, it focus of the development being on a high stability as well as on easy and economical installation. Therefore these fills are built from mechanically joint grids and are easily cleaned. The Net grid packings are high-performance fills which provide an optimized pressure drop.
    Features:
    1) Products suitable for inferior water qualities
    2) Chemical and high temperature resistance of Polypropylene
    3) High stability
    4) Cleaning with high pressures cleaners possible
    5) Long service life
    6) Impact resistant
    7) Environmentally friendly
    8) Economical installation

    Email Details
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy